Optipow

来自删除百科
本条目“Optipow”在中文维基百科已被删除(其它版本),这是一个删除前的存档副本。
Mys 721tx删除了Optipow,理由是:
[[WP:CSD#G11|G11]]: 广告或宣传 ([[WP:TW|TW]])。
这个理由未必准确 (为什么?)

本条目共存留1天:

  • 创建于:2012-03-09
  • 删除于:2012-03-10
  • 贡献者:3人
  • 编辑:9次
  • 浏览:无数据
请阅读免责声明。删除百科只是中文维基百科被删除条目的存档。   Alert icon 建议删除本条目

本条目被标记为快速删除。理由是: 明顯的廣告宣傳頁面,或只有相关人物或團體的聯繫方法的页面。(CSD G11)

ALSTOM :OPTIPOW;EPIC-II,EPIC-III;SIR-E,SIR-IV; EPOQ sole agent: 武汉瑞普克节能环保科技开发有限公司 武汉市武展东路SOGO B座2619#; EPOQ PRODUCT: Patented Product:HV SWITCHING POWER TRANSFORMER;ESP HV TRANSFORMER RECTIFIER;

OPTIPOW® 105, the compact pulse valve for the Optipulse fabric filters of different types: • is a result of many years of experiences within the fabric filter technology area, experiences from the former used membrane type of pulse valve and extensive testing in the SEATC laboratories. • is an ALSTOM patented product (two patents) • is quick acting with high efficiency • has small dimensions, allows valve spacing down to 160 mm. • is primarily designed to be used in combination with circular pressure tank. • is easy to install and make service to • has a very robust design, designed for normal use at air pressure up to 600 kPa (6 bar) but static designed for 1500 kPa ( 15 bar) • the figure 105 stands for the dimension of the plunge. Design data : Design static pressure 15 bar (1500 kPa) Design temperature 100 °C Normal operating pressure < 6 bar Normal operating pressure variation 3 bar unlimited nos Normal operation temperature 50 °C

OPTIPOW® 105 ; ASSEMBLAGE INSTRUCTION

The assemblage of the complete pulse unit (pressure tank+pulse valves) should normally take place in workshop. Detailed instructions for the manufacture as well as mounting and testing of the unit are given in a separate “QUALITY ASSURANCE PRESSURE TANK UNIT FOR FF TYPE LKP” distributed 1999-12-21.

The OPTIPOW valve is as standard made for vertical installation. When the valve shall operate horizontally an extra internal spring has to be used. By that the plunge will always be in closed position when pressurising the cleaning system.

The OPTIPOW is normally delivered as one unit in a special package. For detailed instructions regarding erection of separate parts see OPTIPOW assembly drawing.

Unpack the valves at first when mounting them. Check that there are no visible damages on the valve. Check that there are no foreign materials inside of the valve. Check that the top of the pulse pipe is smooth without any deburrs.

Position numbers below refers to sketch on page 1.

Put the plunge (pos 45) on the top of the pulse pipe. Oil or wet the O-ring on the outer side of the valve house (pos 1) and match the house to the plunge. Turn the house so that the solenoid is pointing in right direction. Screw the four bolts with fingers as long as possible and make then the last setting with tool cross-wise to avoid damages to the O-ring.